投稿日:2024年7月15日

Basics of PH electrodes and their measurement accuracy

They help us measure the pH level, which indicates how acidic or basic a solution is.

Understanding the basics of pH electrodes and their measurement accuracy is vital for anyone working in a laboratory setting.

What are pH Electrodes?

A pH electrode is an electronic device used to measure the pH level of a liquid.

It consists of two main parts: a sensor (or probe) and an electrode.

The sensor detects the hydrogen ion concentration in the solution, while the electrode translates this information into an electrical signal that can be read by a meter.

Types of pH Electrodes

There are different types of pH electrodes, each designed for specific applications.

Common types include:

– Glass electrodes: These are the most widespread and are used in general laboratory applications.

– Combination electrodes: These integrate both the reference and measuring electrodes into one unit.

– Antimony electrodes: Typically used in high-temperature or acidic environments.

How Do pH Electrodes Work?

The working principle of a pH electrode is based on the Nernst equation, which relates the pH of a solution to the electric potential created by the hydrogen ions.

When immersed in a solution, the pH probe generates a voltage proportional to the hydrogen ion activity.

This voltage is then converted into a pH value.

Reference Electrode

Every pH electrode system includes a reference electrode, which provides a stable, known potential to compare against the sensor’s measurements.

Commonly, the reference electrode contains silver chloride or calomel.

Factors Affecting Measurement Accuracy

Accurate pH measurement depends on numerous factors.

Calibration

One of the most critical aspects of accurate pH measurement is regular calibration.

Calibrating a pH electrode involves comparing its readings against solutions of known pH values, termed buffer solutions.

This process should be performed frequently to account for any changes in the electrode’s sensitivity.

Temperature

Temperature significantly affects pH measurement as it influences the electrode’s output voltage.

Many pH meters come equipped with automatic temperature compensation (ATC) to adjust the pH reading based on the solution’s temperature.

If your pH meter does not have ATC, it’s crucial to measure the temperature and manually adjust the readings.

Cleaning and Maintenance

Poorly maintained electrodes can yield inaccurate readings.

Regular cleaning and proper storage are essential for maintaining electrode performance.

Use appropriate cleaning solutions to remove any deposits or contaminants from the electrode’s surface.

Always store the electrode in a proper soaking solution to keep it hydrated and functional.

Electrode Condition

The condition of the pH electrode also influences its accuracy.

Over time, electrodes may wear out or become damaged, reducing their responsiveness.

Inspect electrodes regularly for any signs of wear and replace them as necessary.

Sample Characteristics

The properties of the solution being tested can also affect pH measurements.

High ionic strength, extreme pH ranges, or the presence of certain chemicals can interfere with the electrode’s performance.

Ensure that your electrode is compatible with the characteristics of the solution you are testing.

Best Practices for pH Measurement

Proper Calibration

Always use fresh buffer solutions when calibrating your pH electrode.

Follow the manufacturer’s instructions to ensure accurate calibration.

Regular Cleaning

Clean the electrode after each use to prevent contamination.

This will help maintain accuracy and extend the electrode’s life.

Proper Storage

Store the electrode in an appropriate solution when not in use.

This keeps the bulb hydrated and ready for use.

Consistent Procedures

Follow consistent procedures when taking pH measurements.

Ensure that the electrode is properly immersed in the solution and that the sample is well-mixed.

Common Issues and Troubleshooting

Drifting Readings

If your readings drift, it may indicate a problem with the electrode.

Try recalibrating and checking the electrode’s condition.

Noisy Readings

Noisy or unstable readings can result from air bubbles or electrical interference.

Ensure that the electrode body is fully submerged and away from any sources of electrical noise.

Slow Response

A slow response time may indicate a fouled electrode.

Thoroughly clean the electrode or replace it if necessary.

In summary, understanding how pH electrodes work and the factors influencing their accuracy is essential for obtaining reliable measurements.

By following best practices in calibration, maintenance, and measurement techniques, you can ensure accurate pH readings in your laboratory work.

資料ダウンロード

QCD調達購買管理クラウド「newji」は、調達購買部門で必要なQCD管理全てを備えた、現場特化型兼クラウド型の今世紀最高の購買管理システムとなります。

ユーザー登録

調達購買業務の効率化だけでなく、システムを導入することで、コスト削減や製品・資材のステータス可視化のほか、属人化していた購買情報の共有化による内部不正防止や統制にも役立ちます。

NEWJI DX

製造業に特化したデジタルトランスフォーメーション(DX)の実現を目指す請負開発型のコンサルティングサービスです。AI、iPaaS、および先端の技術を駆使して、製造プロセスの効率化、業務効率化、チームワーク強化、コスト削減、品質向上を実現します。このサービスは、製造業の課題を深く理解し、それに対する最適なデジタルソリューションを提供することで、企業が持続的な成長とイノベーションを達成できるようサポートします。

オンライン講座

製造業、主に購買・調達部門にお勤めの方々に向けた情報を配信しております。
新任の方やベテランの方、管理職を対象とした幅広いコンテンツをご用意しております。

お問い合わせ

コストダウンが利益に直結する術だと理解していても、なかなか前に進めることができない状況。そんな時は、newjiのコストダウン自動化機能で大きく利益貢献しよう!
(Β版非公開)