Understanding the Fundamentals of FTIR Spectrum Analysis
Fourier-Transform Infrared (FTIR) spectroscopy is a technique used to obtain an infrared spectrum of absorption or emission of a solid, liquid, or gas.
The FTIR spectrum analysis is an essential method in the field of chemistry and materials science, as it helps identify materials and determine structural information about molecules.
FTIR works by passing a broad band of infrared light through a sample.
Some of the infrared radiation is absorbed by the sample, and some of it passes through.
The recorded data is called an interferogram, and a series of mathematical transformations, primarily Fourier Transforms, convert this into a spectrum.
The resulting spectrum represents the molecular fingerprint of the sample.
Key Components of FTIR Spectroscopy
At the core of FTIR spectroscopy is the spectrometer, which consists of the following key components:
1. **Source**: The infrared light source generates a wide range of infrared wavelengths. A common source used is a Globar, which is made of silicon carbide.
2. **Interferometer**: The heart of the FTIR, the interferometer, modulates the infrared light to generate an interferogram. It comprises a beam splitter, a fixed mirror, and a movable mirror.
3. **Sample Holder**: The sample can be placed in various forms, such as liquid, solid, or gas, using specific sample holders designed for different materials.
4. **Detector**: The detector measures the intensity of the transmitted or emitted light, typically using a deuterated triglycine sulfate (DTGS) detector for room temperature operation.
5. **Computer and Software**: These are essential for data acquisition, manipulation, and ultimately interpreting the results of the FTIR analysis.
Acquiring FTIR Data Effectively
For effective data acquisition in FTIR spectroscopy, follow these best practices:
Proper Sample Preparation
Ensuring that samples are adequately prepared is critical for obtaining accurate FTIR data.
Solid samples can be ground into fine powders and mixed with potassium bromide (KBr) to form a disk for analysis.
Liquid samples should be loaded into a liquid cell, while gases can be analyzed by flowing them through a gas cell.
Optimize Spectrometer Settings
Adjust the spectrometer settings according to the nature of the sample.
Consider parameters like resolution, scan range, and number of scans.
A higher resolution provides better separation of closely spaced peaks but requires longer acquisition time.
Background Correction
Always perform a background scan before measuring the sample.
This helps to eliminate atmospheric absorption features and other interferences from the final spectrum.
The background should be collected more frequently in environments with fluctuating temperatures or humidity.
Calibration and Validation
Regular calibration of the spectrometer ensures the accuracy of measurements.
Use standard references to validate the spectrometer’s performance to maintain consistency in your results.
Analyzing Foreign Matter Using FTIR
FTIR spectroscopy is a powerful tool for analyzing foreign matter or contaminants in materials.
Here is how it can be effectively used for this purpose:
Identify Foreign Matter
By comparing the unknown foreign spectrum to a library of known spectra, you can identify the material composition of contaminants.
This is useful in quality control processes, where impurities can influence product consistency and performance.
Quantify Contaminants
FTIR can also quantify the concentration of specific foreign particles present in a sample.
By developing calibration curves with known standards, it is possible to determine the amount of a contaminant in a given sample.
Detect Chemical Changes
Foreign matter can cause chemical changes in materials, leading to degradation or altered functionality.
FTIR analysis can detect such changes, helping to maintain material integrity and avoid potential failures.
Conclusion
FTIR spectrum analysis is a valuable technique for understanding the molecular composition and structure of materials.
With know-how in effective data acquisition and foreign matter analysis, FTIR spectroscopy can provide vital insights into material properties and quality control.
By following the guidelines for sample preparation, spectrometer settings, and background correction, you can maximize the accuracy and reliability of your FTIR results.
Whether identifying unknown substances or assessing the purity of materials, FTIR offers a robust solution for material analysis.
資料ダウンロード
QCD管理受発注クラウド「newji」は、受発注部門で必要なQCD管理全てを備えた、現場特化型兼クラウド型の今世紀最高の受発注管理システムとなります。
NEWJI DX
製造業に特化したデジタルトランスフォーメーション(DX)の実現を目指す請負開発型のコンサルティングサービスです。AI、iPaaS、および先端の技術を駆使して、製造プロセスの効率化、業務効率化、チームワーク強化、コスト削減、品質向上を実現します。このサービスは、製造業の課題を深く理解し、それに対する最適なデジタルソリューションを提供することで、企業が持続的な成長とイノベーションを達成できるようサポートします。
製造業ニュース解説
製造業、主に購買・調達部門にお勤めの方々に向けた情報を配信しております。
新任の方やベテランの方、管理職を対象とした幅広いコンテンツをご用意しております。
お問い合わせ
コストダウンが利益に直結する術だと理解していても、なかなか前に進めることができない状況。そんな時は、newjiのコストダウン自動化機能で大きく利益貢献しよう!
(β版非公開)