Mechanism of insulation deterioration and its application to deterioration diagnosis technology for high voltage equipment

Understanding Insulation Deterioration in High Voltage Equipment
Insulation is a crucial component in high voltage equipment, providing the necessary barrier to prevent electrical currents from escaping their intended paths.
Over time, however, insulation can deteriorate, leading to reduced performance and potential failures.
Understanding the mechanism of insulation deterioration is essential for developing effective diagnosis technologies.
What Causes Insulation Deterioration?
Insulation deterioration can be attributed to several factors, each contributing to the weakening of the material’s integrity.
One primary cause is electrical stress.
High voltage equipment operates under significant electrical load, which can cause partial discharges within the insulation.
These microscopic bursts of electricity slowly erode the material, leading to eventual breakdown.
Thermal stress is another significant contributor.
High voltage equipment often generates heat during operation, and over time, this heat can cause the insulation material to lose its vital properties.
Thermal aging results in the insulation becoming brittle, cracked, or even melting in severe cases.
Mechanical stress should not be overlooked.
Insulation materials can suffer from mechanical wear and tear due to vibrations and physical movements.
Repeated stress and moments of tension can cause physical damage, making the insulation less effective.
Lastly, chemical aging processes occur when insulation materials react with their surroundings.
Exposure to moisture, oils, gases, and other contaminants can cause chemical reactions, leading to deterioration.
For instance, the presence of oxygen can cause oxidation, which degrades the insulation.
Detecting Insulation Deterioration: Diagnostic Technologies
Given the significant risks associated with insulation failure, advanced diagnostic technologies have been developed to preemptively identify deterioration and maintain the performance and safety of high voltage equipment.
Partial Discharge Testing
Partial discharge (PD) testing is one of the most popular methods for detecting insulation deterioration.
PD testing involves detecting and measuring small electric charges released during insulation breakdowns.
These discharges are often precursors to larger insulation failures, making early detection critical.
Specialized PD sensors can be installed on high voltage equipment to continuously monitor discharge activity.
Data collected from these sensors can signal deterioration, allowing for timely maintenance actions.
Thermal Imaging
Thermal imaging is another effective diagnostic tool.
By capturing the infrared radiation emitted from equipment, thermal cameras can detect hotspots that indicate insulation issues.
Areas with higher temperatures could signify heat-generating faults or degraded insulation that cannot manage the heat flow properly.
Thermal imaging is non-invasive and provides real-time monitoring, making it a favored choice for routine inspections of high voltage equipment.
Dielectric Insulation Testing
Dielectric testing is a traditional but highly informative procedure where voltage is applied to the insulation system to assess its integrity.
The dielectric response, which refers to how the insulation medium responds to external electric fields, highlights weakened sections or vulnerabilities in the material.
Modern dielectric test equipment can measure tan delta (dissipation factor) and capacitance to determine the quality of insulation.
Higher values typically indicate aging or moisture ingress.
Visual Inspections and Drones
Visual inspections still hold value in detecting insulation issues, especially for identifying physical damage or contamination on the surface of the insulation material.
However, given the size and height of some high voltage equipment, such inspections can be challenging.
Drones equipped with high-definition cameras and sensors now support inspections by accessing difficult areas.
Drones also minimize human risk, providing a safer solution for professionals to evaluate the condition of installations.
Integration of Smart Monitoring Systems
The integration of smart technologies has revolutionized condition monitoring of high voltage equipment.
Sensors and IoT devices can be embedded within the equipment to provide continuous, real-time data on insulation performance.
These smart systems feature analytical software to interpret data quickly and accurately, triggering alerts when unusual patterns suggest insulation deterioration.
Such advancements enable predictive maintenance approaches, reducing unexpected downtimes and extending equipment lifespan.
Advancements in Insulation Materials to Combat Deterioration
The development of innovative materials can also play a vital role in combating insulation deterioration.
Researchers are exploring advanced composite materials that offer superior resistance to electrical, thermal, and mechanical stresses.
Materials like cross-linked polyethylene (XLPE) and ethylene propylene rubber (EPR) are being used increasingly as they provide a robust alternative to traditional insulation materials.
These upgraded materials not only improve performance but also extend the operational life of high voltage equipment.
The Future of Insulation Deterioration Diagnosis
The ongoing research into insulation deterioration mechanisms and the application of advanced diagnostic technologies continue to evolve.
Researchers are working towards combining various technologies to develop comprehensive systems that can detect deterioration with high accuracy and reliability.
Machine learning and artificial intelligence stand to offer further enhancements.
By learning from historical data, these technologies can provide more accurate predictive models for insulation degradation, tailoring maintenance programs based on unique operating conditions.
As technology advances and our understanding of insulation deterioration deepens, the industry will undoubtedly see improvements in the reliability and safety of high voltage equipment.
Such advancements will ensure uninterrupted service, reduced risks, and optimized costs for utilities and consumers alike.
資料ダウンロード
QCD管理受発注クラウド「newji」は、受発注部門で必要なQCD管理全てを備えた、現場特化型兼クラウド型の今世紀最高の受発注管理システムとなります。
ユーザー登録
受発注業務の効率化だけでなく、システムを導入することで、コスト削減や製品・資材のステータス可視化のほか、属人化していた受発注情報の共有化による内部不正防止や統制にも役立ちます。
NEWJI DX
製造業に特化したデジタルトランスフォーメーション(DX)の実現を目指す請負開発型のコンサルティングサービスです。AI、iPaaS、および先端の技術を駆使して、製造プロセスの効率化、業務効率化、チームワーク強化、コスト削減、品質向上を実現します。このサービスは、製造業の課題を深く理解し、それに対する最適なデジタルソリューションを提供することで、企業が持続的な成長とイノベーションを達成できるようサポートします。
製造業ニュース解説
製造業、主に購買・調達部門にお勤めの方々に向けた情報を配信しております。
新任の方やベテランの方、管理職を対象とした幅広いコンテンツをご用意しております。
お問い合わせ
コストダウンが利益に直結する術だと理解していても、なかなか前に進めることができない状況。そんな時は、newjiのコストダウン自動化機能で大きく利益貢献しよう!
(β版非公開)